11.1V 4.4Ah 48.84Wh Li-ion Patient Monitor Battery Compatible with Philips VS1/VS2+ Medical Battery

1
MOQ
USD
harga
11.1V 4.4Ah 48.84Wh Li-ion Patient Monitor Battery Compatible with Philips VS1/VS2+ Medical Battery
fitur Galeri Deskripsi Produk Quote request suatu
fitur
Spesifikasi
Nama Produk:: Baterai Medis
PN:: 453564243501
Model:: 989803174881
Jenis sel:: Baterai lithium-ion
Kondisi:: Baru
Voltase:: 11.1v
Kapasitas:: 4.4Ah
Energi:: 48.84WH
Siklus Kehidupan:: ≥450 kali
Berat:: Sekitar 380G
Ukuran:: 125mm×68mm×32mm
Menyoroti:

11.1V Patient Monitor Battery

,

4.4Ah Medical Battery

,

48.84Wh Li-ion Battery

Informasi dasar
Syarat-syarat pembayaran & pengiriman
Kemasan rincian: Paket Karton
Syarat-syarat pembayaran: T/T, Western Union, Paypal
Deskripsi Produk
Philips VS1 VS2+ Patient Monitor Rechargeable Li-ion Battery

REF 989803174881 | PN 453564243501 | Compatible with VS1 Primary Care Monitor and VS2+ General Practice Monitor

This 11.1V, 4.4Ah lithium-ion battery provides stable power for Philips monitors in mobile healthcare scenarios without fixed power sources. Ideal for transitions between outpatient clinics and injection rooms, as well as community follow-up visits, ensuring continuous monitoring of essential vital signs.

Compatible Devices

This battery supports a wide range of Philips monitors from basic outpatient monitoring to general practice applications:

Compatible Models Monitoring Parameters Single Battery Life Adaptation Scenarios
VS1 HR, SPO2, NIBP 3.5-4 hours Community hospitals and township health centers
VS2+ HR, SPO2, NIBP, Temp 3-3.5 hours Clinics, hospital outpatient clinics
Technical Specifications
Product Name Battery
REF 989803174881
PN 453564243501
Battery Type Lithium-ion battery
Voltage 11.1V
Capacity 4.4Ah
Energy 48.84Wh
Condition New
Charge Time 3.5-4 hours
Cycle Life ≥450 times
Weight About 380g
Size 125mm × 68mm × 32mm
11.1V 4.4Ah 48.84Wh Li-ion Patient Monitor Battery Compatible with Philips VS1/VS2+ Medical Battery 0 11.1V 4.4Ah 48.84Wh Li-ion Patient Monitor Battery Compatible with Philips VS1/VS2+ Medical Battery 1
Frequently Asked Questions
Q1: I'm using a VS1 monitor in a community clinic. After a full charge, the expected battery life is 15 exams, but I've only completed 12. Is this a battery problem?

A1: No. The estimated usage is based on ideal conditions (e.g., NIBP measurements every 60 minutes). Actual use with more frequent measurements (every 30-20 minutes) and longer screen-on time reduces battery life. The difference in exam count doesn't indicate a battery issue.

Q2: Are REF 989803174881 and PN 453564243501 different products? Can they be used interchangeably?

A2: These are different ordering identifiers for the same product. They perform identically and can be used interchangeably.

Q3: During winter community visits, my VS2+ showed fluctuating SpO2 values with battery power that stabilized with external power. Is this battery-related?

A3: Low temperatures affect both battery cells and SpO2 sensor performance. Before winter visits, preheat both battery and monitor for 20 minutes in a warm room. After power-on, perform a dry test to reach operating temperature. Subsequent measurements should show fluctuations within ±1%.